ZETRON 360 Manual de Instruções Página 29

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 28
System Components Configuration
29
Radio Connections
To install the radio and its KCT-19 cable:
1. Follow the directions in the Kenwood installation manual.
2. Plug connector E on the KCT-19 cable into CN4 on the radio PCB.
Radio Interface Configuration
Configuring the radio interface consists of setting jumpers inside the product if necessary.
Most of the jumpers can be left in their default settings. The configurable jumpers and
their functions are described in Table 1. Figure 5 shows the locations of the jum
pers.
Table 1. Configuration Jumpers in the Radio Interface (702-0006)
Jumper Purpose Positions
JP7 Data Polarity
This jumper selects the data polarity. For normal
use, it should be left in position A.
A – Normal
B - Inverted
JP8 Data Termination
This jumper should be set based on the number of
remotes connected to the radio interface.
A - 1 - 5 Remotes
B - 6 - 10 Remotes
C - 11 - 15 Remotes
OUT - 16 - 25 Remotes
JP19 Data Loopback
This jumper loops the data back during self-tests.
It must be in position A for normal operation.
A – Normal
B - Test Mode
JP21 Test
This jumper is used to initiate self-tests. It must be
in position A for normal operation.
A – Normal
B - Test Mode